10 service categories · 100 service pages · Miami-Dade, Broward & Palm Beach
View all services
Flat sections fail at the seams, the terminations and the wall flashing — almost never in the open field. We treat a low-slope roof as its own scope with its own drainage plan, not as a smaller version of the main roof.
Miami-Dade · Broward & Palm Beach Counties
ScrollFlat and low-slope roofing covers the sections a sloped system cannot — additions, garage and porch conversions, ADUs, cabanas, porte-cocheres, and the low-slope portions of otherwise pitched roofs.
On a typical South Florida house this is rarely a whole-roof system. It is usually a hybrid, and treating the flat portion as an afterthought to the main roof is one of the most reliable ways to end up with a leak. Gravity does not clear water off a flat surface the way it clears a steep one, so drainage design, seam quality and wall-flashing detail matter more than material selection on its own. We scope flat sections separately, with their own drainage plan.
No roof marketed as flat is level. Where the structure does not provide the fall, tapered insulation crickets build it.
Water standing longer than roughly two days is a common warranty exclusion and measurably accelerates membrane failure.
Elbaz Construction holds the certified building contractor licence and pulls the roofing permit as contractor of record.
The membrane is the easy part. These are the decisions around it.
A saturated insulation layer under an intact-looking surface is common. Recovering over it traps the water and shortens the new roof to a fraction of its rated life, so it is checked before a system is quoted.
This is the part most often skipped. A membrane laid dead level on a roof with undersized outlets will pond regardless of how good the membrane is, and ponding is what voids the warranty.
TPO gives high solar reflectance and heat-welded, testable seams. Modified bitumen gives substantially greater puncture resistance and a long Florida track record. The right answer depends on how the roof is used, not on preference.
Recovery is cheaper and faster and is sometimes right. It is wrong wherever there is trapped moisture, more existing layers than code allows, or a deck that needs inspection.
This is quoted as a provisional item because it cannot be known in advance. Finding it is the argument for tear-off over recovery on an older roof.
Cover board is what gives the membrane something stable to bond to and adds meaningful resistance to hail and foot traffic.
Weldable seams are probe-tested. A seam that passes a probe is a seam that was actually welded, not merely laid over.
Wall flashing is the most common leak source on these systems, more often than the open field. It gets detailed and inspected accordingly.
System warranties depend on installation to specification and on drainage performance. Both get documented at handover.
Illustrative sequence · not photographs of an Elbaz project
Every image on this page is a generated illustration of low-slope roofing work. None is a photograph, and none shows a roof completed by Elbaz Construction. The re-roof stages are drawn as one building so the sequence reads in order; the detail frames are separate technical illustrations. We hold genuine roofing photography, but it depicts pitched shingle and tile work rather than the low-slope systems this page is about, so it is not used here.




A steep roof sheds water because gravity does the work. A flat roof only sheds water because someone designed a fall into it. A minimum slope of roughly a quarter-inch per foot is what moves water toward drains or scuppers, and where the structure does not provide that, tapered insulation crickets build it. Get this wrong and no membrane saves the roof.
Water standing on a membrane for more than about forty-eight hours is a common trigger for warranty exclusion and measurably accelerates failure. It also concentrates dirt and biological growth, and on an older roof it marks exactly where the deck has already deflected. Ponding is a symptom of drainage design, not of membrane quality.
The open field of a membrane rarely fails on its own. What fails is the laps, the terminations, and above all the wall flashing where the roof meets a vertical surface. Single-ply seams are hot-air welded and can be probe-tested; modified bitumen laps are torched or self-adhered with their own inspection method. Either way, the seam is where the roof is actually made.
TPO is a single-ply membrane with welded seams and high solar reflectivity, commonly rated around twenty to thirty years, and it earns its keep on a hot roof. Modified bitumen is a multi-layer SBS-modified asphalt system with roughly four times the puncture resistance and a long Florida record, commonly rated fifteen to twenty. Foot traffic and rooftop equipment push the answer toward bitumen; energy performance pushes it toward TPO.

Six things we hold to on a low-slope roof.
Every low-slope scope starts with where the water goes. Tapered insulation is specified where the structure does not deliver the slope.
Reflectivity, foot traffic and rooftop equipment decide between single-ply and modified bitumen. Not habit.
Drains and scuppers are positioned at the low points the fall actually creates, and sized for the area they serve.
Recovering over saturated insulation traps water and wastes the new roof. That gets established first.
Weldable laps are probe-tested. Terminations get a bar and sealant, not sealant alone.
Wall and parapet detail gets the attention the field membrane usually gets, because that is where these roofs leak.
South Florida adds three constraints: intense UV and heat load age a membrane faster than the rated life assumes, summer rainfall arrives faster than undersized outlets can clear it, and hurricane wind uplift makes attachment and edge-metal detail a code matter rather than a preference.

Separate technical illustrations rather than part of the sequence above. Each shows a detail that decides whether a low-slope roof reaches its rated life.

Illustration: single-ply membrane installed and seams welded

Illustration: roof drain set into a tapered sump

Illustration: through-wall scupper at the parapet

Illustration: ponding water on a failing roof

Illustration: pipe penetration with a welded boot

The six choices that determine how a low-slope roof performs.
Provenance note: every image on this page is a generated illustration and the diagrams in section 11 are drawings we produced. No image here is a photograph, and none shows a roof completed by Elbaz Construction. We hold genuine roofing photography, but it depicts pitched shingle and tile work rather than the low-slope systems this page covers, so presenting it here would misrepresent the service.
Where the flat sections are, what they cover, and what they are doing now.
Existing build-up, number of layers, deck type, outlet positions and evidence of ponding.
Whether water has already reached the insulation or deck, which decides tear-off versus recover.
Fall, tapered layout where needed, and outlet sizing and position.
Single-ply or modified bitumen, matched to use and exposure, with the warranty terms read.
Roofing permit applied for, with product approval documentation.
Existing system removed where required and any deck damage made good.
Insulation, cover board, membrane, seams, flashing, outlets and edge metal.
Inspections called and attended, warranty documentation registered and handed over.
Requirements, review times and fees differ across Miami-Dade, Broward and Palm Beach and can change, and HVHZ jurisdictions apply their own product-approval rules. Nothing here is a guaranteed approval timeline. We will confirm what your address requires and keep the submission moving.
Drawings, not photographs. A low-slope roof rarely fails in the middle. It fails where the membrane stops.
A minimum slope — commonly around a quarter-inch per foot — moving water to drains or scuppers. Built with tapered insulation where the structure does not provide it.
Hot-air welded on single-ply, torched or self-adhered on modified bitumen. Weldable seams can be probe-tested; that test is the point.
Where the roof meets a vertical wall or parapet. The single most common leak source on these systems.
Vents, curbs and supports, each needing a boot or upstand welded into the field rather than sealed on top of it.
Drains and through-wall scuppers sized and positioned so water actually leaves, not merely heads in the right direction.
We do not publish roofing prices, because area, system, and whether the old roof comes off move the total independently. These are the drivers.
Field membrane down, seams welded and tested, flashing and edge metal complete, outlets clear and the roof falling to them. An illustration of the finished condition rather than a photograph of an Elbaz roof.

Systems, drainage, ponding, seams, permits and cost drivers.
No. Nothing marketed as flat is level. A minimum fall — commonly around a quarter-inch per foot — is required to move water toward drains or scuppers, and where the structure does not provide it, tapered insulation builds it.
TPO is a single-ply membrane with heat-welded seams and high solar reflectivity, commonly rated around 20–30 years. Modified bitumen is a multi-layer SBS system with roughly four times the puncture resistance and a long Florida record, commonly rated 15–20. Foot traffic and rooftop equipment favour bitumen; energy performance favours TPO.
Water sitting on a membrane for more than about forty-eight hours is a common warranty exclusion and measurably shortens membrane life. It is also a symptom — it tells you the fall or the outlets are wrong, which is a design problem rather than a material one.
At the seams, the terminations and above all the wall flashing where the roof meets a vertical surface. The open field of the membrane is rarely the failure point.
Sometimes, and it is cheaper and faster when it is appropriate. It is the wrong call where moisture is already trapped in the insulation, where the layer count would exceed what code allows, or where the deck needs inspecting.
A moisture survey. An intact-looking surface can sit over saturated insulation, and roofing over that traps the water and gives you a fraction of the rated life.
Yes. Low-slope re-roofing is a permitted activity here, and the submission has to identify the system and its product approvals. HVHZ jurisdictions apply their own rules.
Commonly around 20–30 years for a single-ply system and 15–20 for modified bitumen — but those figures assume the roof drains. A ponding roof will not reach them regardless of what the membrane is rated for.
Yes, and that junction deserves specific attention. Most South Florida flat roofing is exactly this hybrid situation, and the transition between the two systems is a detail rather than an afterthought.
Because our genuine roofing photography is of pitched shingle and tile work, not low-slope systems. Rather than show you a pitched roof on a low-slope page, these stages are drawn and clearly labelled as illustrations.
Certified building contractor, licence CBC1265280, bonded and insured.
A separate drainage plan rather than a smaller version of the main roof.
Whether to recover or tear off is decided on evidence, before a system is quoted.
Weldable seams probe-tested; wall and parapet terminations detailed as the primary risk.
Miami-Dade, Broward and Palm Beach, including HVHZ product approval requirements.
Survey, design, permit, installation and inspections coordinated by us.
Product approvals, inspection sign-off and manufacturer warranty registration.
Financing options available through our partners.
Reproduced verbatim from our Google Business Profile. Nothing here has been edited, merged or rewritten.
Redid my whole bathroom and kitchen. Great service - Great quality - very quick - very professional !! Highly recommended!
Adir DavidovGoogle reviewThey are amazing! Very professional. Met my exact requests with so much patience and knowledge. They renovated my whole house and the whole process was such a breeze. I highly recommend them!
Lee MoraliGoogle reviewWe hired them to renovate our investment property and they provided exceptional quality service for an affordable price!
Shir PartushGoogle reviewAmazing experience with the entire company! They did a great job in my house for some work that needed to be completed, and I am extremely happy with the result. Super professional & great service. I highly recommend Elbaz Construction.
Mia ZafraniGoogle reviewAfter I've been Looking for a good company to renovate my house , I found those guys! These people are super professional super honest super Fast !! Don't hesitate to Rent their service! They are number one!!
carmit cohenGoogle reviewI highly recommend them for home improvement. They renovated my master bathroom and a few upgrades for other guest bathrooms. They are very professional, courteous and transparent. They are great at communicating and finding ways to streamline the work. Sean has impeccable project management and customer relationship management skills. Very pleased with the work!
Omri BGoogle reviewProudly serving homeowners across Miami-Dade, Broward and Palm Beach
104 municipalities across three counties — and we hold the licence to build in all of them. Not sure about your address? Ask us.
The useful first conversation is about where the flat sections are, how old they are, and whether you have seen water sitting after rain — because that last answer usually explains the rest.
Licensed, bonded and insured — certified building contractor CBC1265280. Serving Miami-Dade, Broward and Palm Beach.
We have your details and a member of the team will be in touch. If it is urgent, call 754-236-0675.